12V 24V 36W 40W 48W 60W 120W AC/DC Power Supply with CE UL GS certificates

12V 24V 36W 40W 48W 60W 120W AC/DC Power Supply with CE UL GS certificates

Output Power: 101 – 200W
Output Type: Single
Input Voltage: 220V
Output Voltage: 12V
Output Current: 10A
Commodity: 12V 24V 36W 40W 48W 60W 120W AC/DC Power Supply for Webcam
Input Condition: 100 to 240VAC 50/60 Hz 2.0A Max
Input Voltage Range: 90 to 264VAC
Size: 172*72*40mm
Input No Load Power Consumption: 0.5W Max At 115Vac/230Vac
Input Inrush Current:80A Max
Efficiency: 85% Min
Rated Output Power: 36W 40W 48W 60W 120W Max
Output Voltage & Current: 12V 24V DC / 3A / 3.33A/ 4A/ 5A/ 10A
Protection: OCP OVP SCP OPP

MODEL AE-1201000
OUTPUT DC VOLTAGE 12V
RATED CURRENT 10
CURRENT RANGE 0-10A
RATED POWER 120W
RIPPLE&NOISE(max.) Note.2 120mVp-p
VOLTAGE TOLERANCE Note.3 ±5%
LINE REGULATION Note.4 ±0.5%
LOAD REGULATION Note.5 ±1%
SETUP,RISE TIME 100ms,50ms/230VAC 100ms,50ms/115VAC at full load
HOLD UP TIME(Typ.) 20ms/230VAC   10ms/115VAC  at full load
INPUT VOLTAGE RANGE 110-240VAC
FREQUENCY RANGE 47-63Hz
EFFICIENCY(Typ.) 84% min
AC CURRENT(Typ.) 1.5A 230VAC   1.8A/115VAC
INRUSH CURRENT(Typ.) cold start 30A 230VAC
LEAKAGE CURRENT <2mA 230VAC
PROTECTION OVERLOAD Above 105% rated power
Protection type:Hiccup mode,recovers automatically after fault condition is removed
SHORT-CIRCUIT Protection type:Hiccup mode,recovers automatically after fault condition is removed
ENVIROMENT WORKING TEMP. -10℃~+40℃
WORKING HUMIDITY 20%~90%RH
STORAGE TEMP.,HUMIDITY -20℃~+85℃,10%~95%RH
TEMP.COEFFICIENT ±0.03%℃(0-40℃)
VIBRATION 10-500Hz, 2G 10min./1cycle,period for 60min. Each along X,Y,Z, axes
SAFETY WITHSTAND VOLTAGE I/P-O/P:1.8KVAC   I/P-Case:1.8KVAC
OTHERS DIMENSION 170*72*42mm(L*W*H)
PACKING 0.45KG,30PCS/14KGS/0.037CBM
NOTES 1.All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temparature
2.Ripple&noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminal with a 0.1uf&47uf parallel capacitor
3.Tolerance:includes set up tolerance,line tolerance and load tolerance
4.Line regulation is measured from low line to high line at rated load