12v 2a 3a 5a 8a power supplies 12v power adapter for LCD monitor UL SAA CE marked
12v 2a 3a 5a 8a power supplies 12v power adapter for LCD monitor UL SAA CE marked
Model | GHDIDZ-0507000T | GHDIDZ-128000T | GHDIDZ-243000T | |
Output |
DC output voltage | 5V | 12V | 24V |
Output voltage tolerance | ±5% | ±5% | ±5% | |
Rated output current | 7A | 8A | 3.5A | |
Output current | 0~7A | 0~8A | 0~3.5A | |
Output power | 35W | 96W | 84W | |
Ripple and noise | mVp-p | 100mVp-p | 240mVp-p | |
Line regulation | ±1% | ±1% | ±1% | |
Load regulation | ±5% | ±5% | ±5% | |
Voltage adj . range | Fixed | |||
Setup rise hold up time | 500ms,20ms,50ms/230VAC 500ms,20ms,15ms/115VAC at full load | |||
Input |
Input voltage range | 90~264VAC 135~370VDC | ||
AC input current | 0.7A/100VAC | |||
Efficiency | 75% | 80% | 83% | |
AC inrush current | 45A/230VAC | |||
Leakage current | 0.75mA/240VAC | |||
Frequency range | 47~63Hz | |||
Protection
characteristic |
Over load protection | 110%~150%rated output power | ||
Protection mode : Hiccup mode ,auto-recovery after fault condition is removed. | ||||
Over-voltage protection | 105~135% rated output power | |||
Protection mode :Clamp by zener diode,output short | ||||
Environment | Working temperature | 0°C~+50°C | ||
Working humidity | 20%~90% RH non-considering | |||
Storage Temp,humidity | -20°C~+85°C,10~95%RH | |||
Temp.coefficient | ±0.03% /°C(0~50°C) | |||
Vibration | 10~500Hz, 2G 10min./1 cycle ,period for 60 min. each along
X Y Z axes |
|||
Safety | Withstand voltage | I/P-O/P:3000 VDC | ||
Safety standards | EN60950 | |||
Insulation resistance | I/P-O/P:100M Ohms/500VDC/25°C/70%RH | |||
EMI conduction&radiation | Compliance to EN55024, EN61000-3-3 | |||
EMS immunity | Compliance to EN61000-3-3 | |||
Harmonic current | Compliance to | |||
Others | Weight/Packing | 0.32kg/40PCS/14.3kg | ||
Dimension | 170*65*40MM | |||
Connector | Plug | 5.5X2.5mm | ||
Cable | 1.2m | |||
Remark:1.All parameters are specified at 230VAC input, rated load, 27°C 70%RH ambient.
2. Ripple and noise are measured at 20MHz by using a 12 inch Twisted pair terminated with 0.1u and 47u capacitor. 3. Tolerance: includes set up tolerance, line regulation, load regulation. 4. DC voltage : the output voltage set at point measure by plug terminal &50% load. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 20% to 100% rated load. 7.The power supply is considered a component which will be installed into a final equipment .The final equipment must be re-confirmed that it stills meets EMC directives. |